AutoCAD Blocks
We have supplied a set of NFPA Fire Standard symbols to be use with FireManager. All of these blocks have the Attributes needed to link with FireManager. Below is a list of the blocks and how they look:
| Bdr-E1 | This is a standard title block in which the program is designed with. |
| Fire-AUX | This is for a Fire Alarm Aux panel. |
| Fire-BPS | This is for a Fire Alarm Booster Power Supply panel. |
| Fire-Duct | This is for a Duct Mounted Smoke Detector. |
| Fire-FACP | This is for a main Fire Alarm Control Panel. |
| Fire-Heat | This is for a Fire Alarm heat detector. |
| Fire-Module | This is for a Fire Alarm module. It can be either input or output. |
| Fire-MPS | This is for a Fire Alarm Manual Pull Station. |
| Fire-RAL | This is for a Fire Alarm Remote Alarm Light. |
| Fire-RAN | This is for a Fire Alarm Remote Annunicator panel. |
| Fire-Smoke | This is for a Fire Alarm Smoke Detector. |
| Fire-Tamper | This is for a Fire Alarm Sprinkler Tamper Valve. |
| Fire-Waterflow | This is for a Fire Alarm Sprinkler Waterflow Switch. |
| Fire-WM-Aud | This is for a Wall Mounted Audible device. ( Horn, Chime, Speaker) |
| Fire-WM-Aud-Vis | This is for a Wall Mounted Combination Audible-Visible device. |
| Fire-WM-Vis | This is for a Wall Mounted Visible device. ( Strobe only ) |
| Legend | This is for the drawings legend. |
Each of the above listed blocks have these attributes:
| Address: | This is used for your system address. |
| Description: | This is the description to be used for the forms and testing. |
| Panel: | This is the panel number that this device is connected to. The default it 01. |
| Type: | This is the type of device. For example; a smoke detector can be Ion, or Photo. |
| Part-1: | This is one of the parts that is required for this component to be installed. |
| Part-2: | This is one of the parts that is required for this component to be installed. |
| Part-3: | This is one of the parts that is required for this component to be installed. |
| Part-4: | This is one of the parts that is required for this component to be installed. |
| Part-5: | This is one of the parts that is required for this component to be installed. |
| Part-6: | This is one of the parts that is required for this component to be installed. |
| Existing/New: | This is to show in an existing building if a device is either Existing or New for this project. |
Here is what each block looks like.
| Fire-Aux | ![]() |
| Fire-BPS | |
| Fire-Duct | ![]() |
| Fire-FACP | |
| Fire-Heat | |
| Fire-Module | |
| Fire-MPS | |
| Fire-RAL | |
| Fire-RAN | |
| Fire-Smoke | ![]() |
| Fire-Tamper | ![]() |
| Fire-Waterflow | ![]() |
| Fire-WM-Aud | ![]() |
| Fire-WM-Aud-Vis | ![]() |
| Fire-WM-Vis | ![]() |